Changes
- Update default LBT threshold to -80 for AS923 according to Japan regulations
- Enforce downlink payload sizes according by datarate according to channel plan
- One uplink packet must be received before scheduling Class C downlink after a join
- Filter duplicate packets received on wrong channels by comparing RSSI/SNR. Duplicates were seen when end-devices are transmitting close to GW.
Bug Fixes
- Fix: use byte copy routine to stop alignment trap logged on join
- Fix: Calculation for max gateway tx power per channel plan with antenna gain. US915, AU915, IN865 plans