Unable to login on web interface
- This topic has 5 replies, 5 voices, and was last updated 7 years ago by .
Viewing 6 posts - 1 through 6 (of 6 total)
Viewing 6 posts - 1 through 6 (of 6 total)
- You must be logged in to reply to this topic.
Tagged: Conduit
Hi there,
I am unable to login on web interface. I am successful in connecting via ssh using ethernet cable. My device ip address is 192.168.2.10.
Looking forward for some solution
Thank You
Hello Chandan
Please provide a “serial number” and model number of the device you cannot log into.
-Best Regards
Hi there,
I found same issue on my new Conduit, MTCDT – LEU1 246L -868-EU, I can log in via ssh but as root user (admin not working, why???) but not via http. I checked correct IP on PC and unit by console. ping works but not http
below an extract of my console:
MultiTech Systems mLinux GNU/Linux
mLinux 3.3.24 mtcdt /dev/ttyS0
Version: 3.3.24
Date: 2018-03-27T16:32:00
mtcdt login: admin
Password:
Login incorrect
mtcdt login: root
Password:
root@mtcdt:~# ps
PID TTY TIME CMD
779 ttyS0 00:00:00 login
1191 ttyS0 00:00:00 sh
1204 ttyS0 00:00:00 ps
root@mtcdt:~# opkg list_installed | grep packet
lora-packet-forwarder – 3.1.0-r11.0
lora-packet-forwarder-usb – 1.4.1-r11.0
root@mtcdt:~# cd /opt/lora/
root@mtcdt:/opt/lora# ls
README.md
basic_pkt_fwd-usb
beacon_pkt_fwd-usb
forwarder-utils
gateway-utils
global_conf.json
global_conf.json.MTAC_LORA_1_0
global_conf.json.MTAC_LORA_1_0.EU868
global_conf.json.MTAC_LORA_1_0.US915
global_conf.json.MTAC_LORA_1_5
global_conf.json.MTAC_LORA_1_5.AS923
global_conf.json.MTAC_LORA_1_5.AS923-LBT
global_conf.json.MTAC_LORA_1_5.AU915
global_conf.json.MTAC_LORA_1_5.EU868
global_conf.json.MTAC_LORA_1_5.IN865
global_conf.json.MTAC_LORA_1_5.KR920-LBT
global_conf.json.MTAC_LORA_1_5.US915
gps_pkt_fwd-usb
ln-lora-spi-dev.sh
local_conf.json
lora-network-server
lora-network-server.conf.full
lora-network-server.conf.sample
lora_pkt_fwd
util_ack-usb
util_sink-usb
root@mtcdt:/opt/lora# cat /opt/lora/global_conf.json | grep gateway_ID
“gateway_ID”: “<WILL-BE-AUTO-REPLACED-WITH-LORA-EUI>”,
I tried to reset factory default using frontal button but without success.
Do you know any trick to fix my issue?
I’m looking forward your kind help.
Thanks
mLinux firmware does not provide a Web interface.
AEP firmware is needed.
Thanks a lot for clarification
can I load AEP into my unit? Procedure?
If you create a Multitech Support Portal Case at https://support.multitech.com they have a procedure for converting to AEP.