{"id":8083,"date":"2015-06-22T09:54:59","date_gmt":"2015-06-22T14:54:59","guid":{"rendered":"http:\/\/www.multitech.net\/developer\/?page_id=8083"},"modified":"2022-09-14T15:36:21","modified_gmt":"2022-09-14T20:36:21","slug":"getting-started-with-lora-conduit-aep","status":"publish","type":"page","link":"https:\/\/www.multitech.net\/developer\/software\/lora\/getting-started-with-lora-conduit-aep\/","title":{"rendered":"Getting Started with LoRa Conduit AEP (LoRa Configuration)"},"content":{"rendered":"<h3><em style=\"font-size: 13px;\"><strong>This\u00a0section only applies to devices with\u00a0mPower<sup>\u2122<\/sup> and LoRa. For the Conduit<sup>\u00ae<\/sup>, LoRa cards are typically sold separately.<\/strong><\/em><\/h3>\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=Q_25lZWcSWI&amp;t=6s\">https:\/\/www.youtube.com\/watch?v=Q_25lZWcSWI&amp;t=6s<\/a><\/p>\n<p><iframe loading=\"lazy\" src=\"http:\/\/www.youtube.com\/embed\/Q_25lZWcSWI\" width=\"550\" height=\"315\" frameborder=\"0\"><\/iframe><\/p>\n<p>Before setting up LoRa, your device should be connected and powered up. If not refer to installation information for your device.<\/p>\n<ul>\n<li>For Conduit installation, see the <a href=\"https:\/\/www.multitech.com\/documents\/publications\/quick-start-guides\/82101453L-Conduit-Quick-Start-Guide.pdf\">Conduit Quick Start Guide<\/a>.<\/li>\n<li>For Conduit Access Point installation, refer to the Quick Starts or User Guides available through <a href='https:\/\/www.multitech.net\/developer\/products\/multiconnect-conduit-access-point\/' title='Conduit AP'>Conduit AP<\/a><\/li>\n<li>For Conduit IP67 Base Station, refer to the Installation Guide for your model, available through <a href='https:\/\/www.multitech.net\/developer\/products\/multiconnect-conduit-platform\/basestation\/' title='Conduit IP67 Base Station'>Conduit IP67 Base Station<\/a><\/li>\n<\/ul>\n<h3>Getting Started with LoRa<\/h3>\n<ol>\n<li>Login to the web management interface. Refer to\u00a0<a href=\"https:\/\/www.multitech.com\/documents\/publications\/software-guides\/s000727--mPower-Edge-Intelligence-Conduit-AEP-software-guide.pdf\">the software guide<\/a> if needed.<\/li>\n<li>Access the LoRaWAN Network Settings by going to <strong>LoRaWAN &gt; Network Settings<\/strong>\u00a0on the left sidebar. See LoRaWAN Network Settings\u00a0in <a href=\"https:\/\/www.multitech.com\/documents\/publications\/software-guides\/s000727--mPower-Edge-Intelligence-Conduit-AEP-software-guide.pdf\">the software guide<\/a> for details.<\/li>\n<li>To modify advanced settings, click <strong>Show Advanced Settings<\/strong>. For more details, see\u00a0LoRaWAN Network Settings in\u00a0<a href=\"https:\/\/www.multitech.com\/documents\/publications\/software-guides\/s000727--mPower-Edge-Intelligence-Conduit-AEP-software-guide.pdf\">the software guide<\/a>.<\/li>\n<li>For configuring as a Packet Forwarder, select <strong>Packet Forwarder<\/strong> from\u00a0<strong>Mode<\/strong> under <strong>LoRa Mode<\/strong>.\u00a0For more details, see\u00a0LoRaWAN Network Settings\u00a0in\u00a0<a href=\"https:\/\/www.multitech.com\/documents\/publications\/software-guides\/s000727--mPower-Edge-Intelligence-Conduit-AEP-software-guide.pdf\">the software guide<\/a>.<\/li>\n<\/ol>\n<h3>Setting Up an mDot<\/h3>\n<ol>\n<li>Establish a serial connection to the\u00a0mDot<sup>\u2122<\/sup>\n<ol>\n<li>Connect your PC to the DB9 serial connector on the UDK<\/li>\n<li>Open a terminal session using an application such as <a href=\"http:\/\/ttssh2.osdn.jp\/\">TeraTerm<\/a> with baud rate 115,200<\/li>\n<\/ol>\n<\/li>\n<li>Issue these commands with the same values you set for the gateway:\n<ul>\n<li><code>AT+FSB=value<\/code> (915 NA only | value = frequencySubBand from your LoRa gateway)<\/li>\n<li><code>AT+NI=1,value<\/code> (value = Network Name for your LoRa gateway)<\/li>\n<li><code>AT+NK=1,value <\/code>(value = Network Passphrase for your LoRa gateway)<\/li>\n<li><code>AT&amp;W <\/code>(save settings)<\/li>\n<li><code>ATZ <\/code>(restart)<\/li>\n<\/ul>\n<\/li>\n<li>Join the network: <code>AT+JOIN<\/code><\/li>\n<li>Send data with ACK requested:\n<ul>\n<li><code>AT+ACK=1<\/code><\/li>\n<li><code>AT+SEND=hello world<\/code><\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<p style=\"text-align: center;\"><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.multitech.net\/developer\/wp-content\/uploads\/2015\/08\/mdot-setup.png\" alt=\"screenshot of mDot setup\" \/><\/p>\n<h3>Next Steps<\/h3>\n<ul>\n<li><a href='https:\/\/www.multitech.net\/developer\/software\/lora\/conduit-aep-lora-communication\/' title='Conduit mPower: LoRa Communication and Node-RED'>Conduit mPower: LoRa Communication and Node-RED<\/a><\/li>\n<li><a href='https:\/\/www.multitech.net\/developer\/software\/lora\/troubleshooting-lora-communication\/' title='Troubleshooting LoRa Communication'>Troubleshooting LoRa Communication<\/a><\/li>\n<li><a href=\"https:\/\/www.multitech.com\/documents\/publications\/dot-net-files\/LoRaWANTroubleShootingGuide-09202018.pdf\">Troubleshooting Guide<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>This\u00a0section only applies to devices with\u00a0mPower\u2122 and LoRa. For the Conduit\u00ae, LoRa cards are typically sold separately. https:\/\/www.youtube.com\/watch?v=Q_25lZWcSWI&amp;t=6s Before setting up LoRa, your device should be connected and powered up. If not refer to installation information for your device. For Conduit installation, see the Conduit Quick Start Guide. For Conduit Access Point installation, refer to [&hellip;]<\/p>\n","protected":false},"author":1235,"featured_media":0,"parent":8462,"menu_order":5,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"class_list":["post-8083","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.multitech.net\/developer\/wp-json\/wp\/v2\/pages\/8083","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.multitech.net\/developer\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.multitech.net\/developer\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.multitech.net\/developer\/wp-json\/wp\/v2\/users\/1235"}],"replies":[{"embeddable":true,"href":"https:\/\/www.multitech.net\/developer\/wp-json\/wp\/v2\/comments?post=8083"}],"version-history":[{"count":88,"href":"https:\/\/www.multitech.net\/developer\/wp-json\/wp\/v2\/pages\/8083\/revisions"}],"predecessor-version":[{"id":33195,"href":"https:\/\/www.multitech.net\/developer\/wp-json\/wp\/v2\/pages\/8083\/revisions\/33195"}],"up":[{"embeddable":true,"href":"https:\/\/www.multitech.net\/developer\/wp-json\/wp\/v2\/pages\/8462"}],"wp:attachment":[{"href":"https:\/\/www.multitech.net\/developer\/wp-json\/wp\/v2\/media?parent=8083"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}