sntp – Conduit

Description : settings for clock synchronization between computer systems : OBJECT

Element Type Description
pollingTime UINT Frequency in minutes to poll current time (default:120) [0-1440]
timeZones ARRAY Specifies the list of all timezones
enabled BOOL enable or disable SNTP client (default:false)
servers ARRAY List of ip address or domain name of sntp servers
timeZone STRING Zoneinfo file path to use as timezone : (default:UTC)