MTAC-GPIO Power Draw

The following power draw values were measured with the MTAC-GPIO card installed in a MultiConnect Conduit device.

Voltage Typical Power – No Connection (Amps) Typical Power w/Ethernet Cable Attached (Amps) Max Power – Passing Data Stream (Amps) Total Inrush Charge Duration During Power Up (mSec) Total Inrush Charge in MilliCoulombs (mC)
9.0 Volts 0.166 0.180 0.241 8.31 8.36
20.0 Volts 0.093 0.099 0.125 8.55 8.52
32.0 Volts 0.074 0.077 0.092 29.6 28.8

MultiConnect® Conduit™ Power Draw

If using a MultiConnect Conduit with the mCard, factor your model’s power draw into your power calculations.