MTAC-GPIO Power Draw

The following power draw values were measured with the MTAC-GPIO card installed in a Conduit® device.

Voltage Typical Power – No Connection (Amps) Typical Power w/Ethernet Cable Attached (Amps) Max Power – Passing Data Stream (Amps) Total Inrush Charge Duration During Power Up (mSec) Total Inrush Charge in MilliCoulombs (mC)
9.0 Volts 0.166 0.180 0.241 8.31 8.36
20.0 Volts 0.093 0.099 0.125 8.55 8.52
32.0 Volts 0.074 0.077 0.092 29.6 28.8

Conduit Power Draw

If using a Conduit with the mCard™, factor your model’s power draw into your power calculations.

  • MTCDT-246 Models Power Draw [the linked post is not published yet]
  • MTCDT-247 Models Power Draw [the linked post is not published yet]
  • MTCDT-210 Models Power Draw [the linked post is not published yet]