Conduit Specifications

DRAFT ONLY

The following are the specifications for the Conduit.

Category Description
Physical Description
Dimensions See the Conduit Dimensions Drawing
Weight 15.6 oz. (442.25 grams) with no accessory cards installed
Connectors
Connectors 1 USB device micro Type B debug port (behind nameplate)
1 RJ-45 Ethernet port
2 USB ports (1 USB DEVICE micro Type B, 1 USB HOST Type A)
2 cellular antenna connectors
1 Wi-Fi/Bluetooth connector
1 GPS antenna connector
Power Requirements
Input Voltage 9-32 Volts
Power Draw See Conduit Power Draw
Environment
Operating Environment -30° to +70° C 1
Storage Environment -40° to +85° C
Relative Humidity 20 to 90% non-condensing
Certifications
Radio & EMC Compliance EN 55022:2010
EN 301 489
FCC Part 15 Class B
IC Class B
Safety Compliance UL/cUL 60950-1 2nd Ed.
IEC 60950-1 2nd Ed. Am.1 and Am. 2
Telecom Approvals Based on the radio installed

1UL Listed @ 40° C, limited by AC power supply. UL Recognized @ 65° C for Conduit LTE devices within IP67 enclosure or when used with the fused DC power cable, part number FPC-532-DC.

Installation in outdoor locations or ambient above 70° C has not been evaluated by UL. UL Certification does not apply or extend to use in outdoor applications.

Optional power must be UL Listed ITE power supply marked LPS or Class 2 rated 12 VDC, 5A. Certification does not apply or extend to Voltages outside certified range, and has not been evaluated by UL for operating voltages beyond tested range.